HOME
PRODUCTS
IMPRESSUM
CONTACT
deutsch english

Bit Pattern Generators
up to 60 Gbit/s

Multichannel Pattern Generators
up to 120 Gbit/s

Pattern Generators
with ternary output

Multilevel
Pattern Generators

Bit Pattern Receivers
up to 40 Gbit/s

Samplingoscilloscopes
TDR Measurement

Customized Special Developments

Bit Error Rate Tester SBF 40G

Bitmusterempfänger / Bit Error Rate Tester SBF 40G
Download
(30KB)

Front panel view of the SBF 40GIG

Key Features

  • Self-synchronizing, wideband Pattern Receiver with error counters
  • Bitrate 1 ... 40 GBit/s
  • Latest technology using SiGe and InPh integrated circuits
  • Operation via front panel or graphical user interface on PC (via USB-port)

Brief description

The Pattern Receiver SBF 40G is designed to be used for bit error rate testing together with the Pattern Generators BPG 30G, BPG 40G 128M or BPG 60G.

Benutzeroberfläche der Steuerungssoftware

The Pattern Receiver SBF 40G is used to detect errors contained in a data stream.

Synchronous clock and data signals are needed to perform a measurement. Four different pseudo random binary sequences (PRBS) of length 27-1, 215-1, 223-1 and 231-1 structured according to the CCITT standard can be analysed using bitrates between 1 and 40 GBit/s.

Two different error rates can be measured: Errors per Bit and Errors per Time. The time interval for error measurements can be choosen between 105 and 1014 bit periods for the Error/Bit measurement and between 10-5 and 104 seconds for the Error/Time measurement.

The instrument can be operated locally via the front panel or remotely controlled via its USB-interface. An easy-to-use graphical user interface is included in the supplied software. Additionally self-programmed software may be used to control the instrument.

Technical Specifications

SBF 40GIG
Synchronisation 1 GBit/s ... 40 GBit/s (with external clock)
Frame synchronisation automatically,
Phase tolerance between Data and Clock:
+/- 20% of the clock periode
Phase shifting: +/- 15ps by adjustable delay
Synchronisation is displayed by LED.
Clock Input 50 Ohm SMA, AC-coupled, |r| < 0.2,
Ui = 0.3 ... 1.0 Vpp, selectable between:
1 Ghz ... 40 Ghz (Clock) and
0.5 Ghz ... 20 Ghz (Clock/2)
Pattern PRBS: 231 - 1, 223 - 1, 215 - 1, 27 - 1
Data Input NRZ or /NRZ, selectable,
Ui = 0.3Vpp ... 1Vpp, 50 Ohm SMA, |r| < 0.2,
manually selectable threshold
Trigger Outputs
  1. Clock/64, 1 Vpp, AC-coupled, 50 Ohm SMA
  2. Word Frame Trigger, 0.8 Vpp, 50 Ohm SMA
Error Counter Error rate measurement (Resolution 6 digits):
  1. Error/time: 107 ... 10-4 /s-1
    Gate Time: 10µs ... 10.000 s
  2. Error/Bit: 10-3 ... 10-14
    Gate Time: 105 ... 1014 Bits
Single or repetitive
Power Supply 115V/230V/50Hz-60Hz/80VA
Dimensions 19" desktop, W x H x D = 470 x 150 x 370 mm
Weight approx. 9kg


The instrument is produced by SYMPULS in Germany.
We offer a reliable service and 24 month warranty.